- Color LCD for gas concentration display and various settings
- Audio alarm (voice message) is available in four languages
*Only English and Japanese are available for on-screen languages.
- Improved operability with jog dial
- Optional backup power supply unit to provide emergency power in the event of power outage
*Max.7 days (diffusion type) or 2 days (extractive type) during intermittent gas monitoring and max.120 min. During continuous gas monitoring after power outage.
Model |
NV-120Cv / NV-120Ci |
Detection Principle |
Combustion |
Target Gas |
Combustible gas |
Power Voltage |
AC type: 100 to 240 VAC±10% or DC type: 24 VDC (18 to 26.4 VDC) *1 |
Power Consumption*2 |
AC type
Non-backup power type: Standard 2.0 VA (Max. 3.4 VA)
Backup power type: Standard 2.1 VA (Max. 4.7 VA)
DC type
Non-backup power type: Standard 2.0 W (Max. 3.4 W) |
External Outputs |
・Power output: 24 VDC ± 10% Max.0.3 A
・Signal output: 4-20 mA analog or 1-5 V *1
In the event of failure: ≤ 0.6 mA (for 4-20 mA type) and ≤ 0.25 V (for 1-5 V type)
・1st stage gas alarm contact: Dry, N.O. or N.C.*1
Max. load: 250 VAC 2 A, 30 VDC 2 A (resistive load)
・2nd stage gas alarm contact : Dry, N.O. or N.C.*1
Max. load: 250 VAC 2 A, 30 VDC 2 A (resistive load)
・Fault contact: Dry, N.O. or N.C.*1
Max. load: 250 VAC 2 A, 30 VDC 2 A (resistive load)
・Audio alarm contact: Dry, N.O.
Max. load: 250 VAC 2 A, 30 VDC 2 A (resistive load) |
Display |
Color LCD with backlight |
Status Indicator |
Green POWER LED, red ALARM LED (1st stage gas alarm: flashes and 2nd stage gas
alarm: flashes rapidly) and amber FAULT LED |
Gas Alarm |
・1st stage gas alarm: ALARM LED flashes red + LCD turns orange + beeping + voice
message “Gas alarm”
・2nd stage gas alarm: ALARM LED rapidly flashes red + LCD turns red + fast beeping + voice message “Gas alarm” |
Fault Alarm Indication |
FAULT LED lit amber + error code on display + fast beeping + voice message*3 |
Compliance |
RoHS directive (2011/65/EU) *4 |
Color |
Case and cover: DIC546 1/2 Backup battery unit: Munsell 10Y8.5/1 |
Mass |
Non-backup power type: Approx. 750 g
Backup power type: Approx. 2.2 kg |
Dimensions |
Non-backup power type: W113 mm×D77 mm×H219 mm
Backup power type: W113 mm×D115 mm×H234 mm |
Operating Temperature |
Non-backup power type: –10 to 50°C
Backup power type: 0 to 40°C No rapid temperature change. |
Operating Humidity |
0 to 90%RH No condensation. |
Backup Power Type*1 and 5 |
Without intermittent gas-monitoring mode:
In the event of a power outage, the unit will continue continuous gas-monitoring for another 120 minutes or more.
With intermittent gas-monitoring mode*6 and 7:
In the event of a power outage, the unit will continue continuous gas-monitoring for another 120 minutes, followed by intermittent monitoring (10 seconds each at 15-minute intervals). The intermittent monitoring will last for max. 7 days when connected to diffusion type gas detector and max. 2 days when connected to extractive type. |
*1. Must be specified at the time of ordering.
*2. Consumption power of the connected gas detector is excluded.
*3. Voice message changes depending on the nature of the fault.
*4. None of the hazardous substances restricted by the RoHS directive is used in this product.
*5. Backup power type units are all AC type units.
*6. Only NV-120Ci and NV-120Cv models have intermittent gas-monitoring mode.
*7. Gas alarm accuracy is compromised during the intermittent gas-monitoring mode, since the sensor output becomes unstable during this mode, as a result, a gas alarm may be activated even though the concentration does not reach the gas alarm set value.
*Only New Cosmos-manufactured gas detector can be connected to this product.
*Specifications above may be subject to change without notice.
*N.O.: Normally open. *N.C.: Normally closed.
Connectable Detectors