Sensor for SDE- PS-7-010-0(ROHS), SDE-CDS-7-7BNH50

$455.50

Sensor for SDE- PS-7-010-0(ROHS)
For detecting gas leaks in semiconductor factories

Available on backorder

SKU: SDE-NV-120Cv-1 Category:
  • Gas detection unit for semiconductor factories.
  • Replacement sensors are pre-calibrated using the ” New Cosmos Method*”, eliminating the need for onsite gas calibration.
  • Our proprietary hot wire semiconductor hydride sensor provides a long service life (coming soon).
  • Large LCD with allows for easy onsite monitoring at a glance.
  • PoE compatible for reduced wiring and seamless PLC connection.
  • Front access for easy sensor replacement.
  • Sub/expansion units allow for the combination of sensors based on the desired type and quantity of gas.

*What is the New Cosmos method?
A method introduced in 1997 that eliminates the need for gas calibration at the installation site and reduces running costs by recycling sensors.

Model Main unit: PS-8N, PS-8M
Sub unit: PS-8S
Sensor Detection Principle Electrochemical cell, Hot wire semiconductor, Galvanic cell
Sampling Method Pump suction type (approx. 0.5L/min ±20% automatic suction flow rate control)
Target Gas Set to user specifications
Detection Range Set to user specifications
Display Monochrome LCD full dot display
Gas concentration: 5-digit display(with units)
Others: Gas name display, flow rate status indicator, alarm (1st and 2nd stage) status indicator, fault alarm display
*Not available for PS-8S. display on main unit
Alarm Set Value Set to user specifications
Alarm Accuracy Combustible gas : ±25% of alarm set value (under equivalent conditions)
Toxic gas : ±30% of alarm set value (under equivalent conditions)
Oxygen deficiency: ±1vol% (under equivalent conditions)
Alarm Delay Combustible gas : within 30 seconds at 1.6 times the alarm set value
Toxic gas : within 60 seconds at 1.6 times the alarm set value
Oxygen deficiency: within 5 seconds at 10 vol% until the concentration reaches 18 vol% (at 20±2°C)
(Excluding pipe length and communication time for all gases listed above)
Alarm Display Gas alarm 1st stage: Alarm 1 LED (red) flashes, LCD screen display ALARM1
Gas alarm 2nd stage: Alarm 2 LED (red) flashes, LCD screen display ALARM2
External Outputs [Digital signal*1]
・PS-8M: Ethernet 10BASE-T/100base-Tx(Modbus/TCP)
Modbus/TCP (Maximum number of connections depends on system configuration)
Maximum transmission distance 100m (up to HUB)
・PS-8N, PS-8S: None *PS-8N: RS485 (Modbus-RTU) when using the expansion unit MR module
[Gas concentration analogue signal*2]
・PS-8N, PS-8M: DC4-20mA (common negative terminal with power source) (output accuracy: within FS ±0.5%)
*0.6mA or less when a fault alarm indication occurs *300Ω or less including wiring resistance [Collective gas alarm contact(1st and 2nd stage), collective fault alarm indication contact*3]
1a non-voltage contact/ automatic return
*Rated load: AC125V 0.5A or DC30V 1.0A (resistive load)
*Individual contact outputs require an expansion unit.
Explosion-proof Performance Non-explosion-proof
Operating Temperature and Humidity Range 0℃ to 40℃ (given no sudden changes), 30 to 85% RH (given no condensation)
Power Source Used ・PS-8N: DC24V±10%
・PS-8M: DC24V±10% or PoE (Power over Ethernet, IEEE 802.3at)
・PS-8S: Supplied from the main unit
power consumption*4 CDS-7: 3.5W (max. 5.2W)
CDS-7 (catalytic conversion type): 4.0W (maximum 5.9W)
COS-7: 3.5W (max. 5.2W)
CHS-7: 4.0W (max. 5.9W)
dimensions, mass ・PS-8N, PS-8M: W70mm x H124mm x D172mm (excluding protrusions), approx. 850g (excluding sensor)
・PS-8S: W70mm x H124mm x D172mm (excluding protrusions), approx. 770g (excluding sensor unit)